Product Details:
Payment & Shipping Terms:
|
Standard: | IEC61000-4-2, GJB128A, IEC61000-6-1, IEC61326 | Output Voltage: | 30KV |
---|---|---|---|
Function: | Contact Discharge, Air Discharge | Warranty: | 12 Months |
Usage: | EMC Test System | Working Power: | AC 220VV,50/60Hz |
Highlight: | electrostatic discharge generator,emc testing services |
Air and Contact Electrostatic Discharge (ESD) Simulator up to 30KV EMC Test System IEC61000-4-2
1. Introduction
Electrostatic Discharge (ESD simulator is completely meet the requirements of IEC61000-4-2 and GB/T17626.2. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. Electrostatic discharge generator is widely apply to the fields of industry control equipment, household appliance, chemical electronics,communication electronics,components, auto control equipment and etc.
ESD generator is to simulate electrostatic discharge, it belongs to EMC test according to IEC61000-4-2, there is two test methods: contact discharge and air discharge, the test voltage extends from 0.1KV to 30KV, user can freely choose and define the test grade.
The ESD generator is consisted by ESD generator, ESD gun and two electrodes (cone sharp electrode is for contact discharge, and ball sharp electrode is for air discharge), the parameters of rising time, peak current and current at 30ns and 60ns are strictly meet the requirement of IEC61000-4-2.
2. Features
1) The air discharge completely meet the standard requirement to keep the voltage for 5s above, and do not affect by air humidity, with good repeatability.
2) Built in IEC standard voltage, with auto trigger and user-defined function.
3) HV protection, over current protection and short circuit protection.
3. Parameter
Output voltage | ESD-2005 | 0.5~30kV±5% | |
Polarity | Positive, negative | ||
Trigging mode | SINGLE | single | |
COUNT | Discharge according to the set number | ||
20pps | 20 times/second | ||
* | Host self-trigger, voltage auto-evolving scan | ||
Discharge mode | Air discharge, contact discharge | ||
Discharge Interval | 0.1~9.9s(0.05s@ 20pps mode) | ||
Counter | 0~999 (Discharge count) | ||
Resistor kit | 150pF±10%, 330Ω±10% | ||
discharge electrodes | Conical contact discharge electrode and spherical air discharge electrode | ||
Air discharge voltage keep time | More than 5s | ||
Working environment | Ambient temperature:10℃~35℃ humidity:30%~60% | ||
Power | Single AC85~265V,50/60Hz | ||
Dimension and weight | 250×210×130mm(D×W×H)/4kg |
4. Operation Interface
5. FAQ
1). What is the warranty period of the equipment?
Answer: the equipment warranty is 12 months upon you receipt of the equipment
2). Can you provide third-lab calibration certificate?
Answer: Yes, the equipment can send to the third-labs authorized by ISO17025 and get the calibration certificate, but the buyer should undertake the charges.
3). Does this equipment has English operation interface?
Answer: of course, yes, the operation interface has English instruction.
4). Your power plug can not be used in our country, can you change it for us?
Answer: yes, we will change the power plug to fit your demands, please subbmit this issue when you make order.
Contact Person: Ms. Penny Peng
Tel: +86-18979554054
Fax: 86--4008266163-29929